How To Solve The Problem Of The Reduction Box Of The Tablet Press?
The tablet gear reducer consists of a worm gear-worm and a casing. A common failure of the tablet gear reducer is the gearbox leakage. The main cause of failure is caused by loose flange screws or aging oil seals. How to solve the problem of the reduction box of the tablet press?
A very simple solution is to tighten the flange screws or replace the oil seal and apply sealant. In fact, we understand the operating principle of the tablet press. After using it for a long time, we have a lot of experience, so we can naturally determine exactly what is wrong. Malfunction